Collet, A., Bragard, J., & Dauby, P. (2017). Temperature, geometry, and bifurcations in the numerical modeling of the cardiac mechano-electric feedback. Chaos, 27 (9), 093924. doi:10.1063/1.5000710 Peer Reviewed verified by ORBi |
Collet, A. (2015). Numerical modeling of the cardiac mechano-electric feedback within a thermo-electro-mechanical framework. Study of its consequences on arrhythmogenesis [Doctoral thesis, ULiège - Université de Liège]. ORBi-University of Liège. https://orbi.uliege.be/handle/2268/181760 |
Pironet, A., Desaive, T., Kosta, S., Lucas, A., Paeme, S., Collet, A., Pretty, C., Kolh, P., & Dauby, P. (2013). A multi-scale cardiovascular system model can account for the load-dependence of the end-systolic pressure-volume relationship. BioMedical Engineering OnLine, 12 (1), 8. doi:10.1186/1475-925X-12-8 Peer Reviewed verified by ORBi |
Soret, L., Gérard, J.-C., Collet, A., Piccioni, G., & Drossart, P. (September 2012). Time evolution of the O2 IR Atmospheric nightglow: VIRTIS observations and comparison with a 2-D model [Paper presentation]. European Planetary Science Congress, Madrid, Spain. Peer reviewed |
Collet, A., Desaive, T., & Dauby, P. (2012). Autonomous electrical activity induced by cardiac tissue deformation in a thermo-electro-mechanical background. In 8th IFAC Symposium on Biological and Medical Systems. Peer reviewed |
Collet, A., Desaive, T., & Dauby, P. (2012). Modèle unidimensionnel instationnaire de l'activité pacemaker cardiaque induite par le feedback mécano-électrique dans un environnement thermo-électro-mécanique. Annales de Cardiologie et d'Angeiologie. doi:10.1016/j.ancard.2012.04.019 Peer Reviewed verified by ORBi |
Collet, A., Desaive, T., & Dauby, P. (2011). Effects of temperature on pacemaker activity induced by mechano-electric feedback in a one-dimensional model of a ring-shaped cardiac fiber. In NCBME (Ed.), 10th Belgian Day on Biomedical Engineering. Peer reviewed |
Collet, A., Desaive, T., & Dauby, P. (02 December 2011). Effects of temperature on pacemaker activity induced by mechano-electric feedback in a one-dimensional model of cardiac fiber [Poster presentation]. 10th Belgian Day on Biomedical Engineering, Bruxelles, Belgium. |
Collet, A., & Dauby, P. (2011). One-dimensional time-dependent model of cardiac pacemaker activity generated by mechano-electric feedback in a thermo-electro-mechanical context. Archives des Maladies du Coeur et des Vaisseaux. Pratique, (Hors-série 3), 20. Peer Reviewed verified by ORBi |
Collet, A., Desaive, T., Pierard, L., Boman, R., & Dauby, P. (05 July 2011). Influence of thermoelectric coupling on pacemaker activity generated by mechano-electric feedback in a one-dimensional ring-shaped model of cardiac fiber [Poster presentation]. XXIIIrd congress of the International Society of Biomechanics, Brussels, Belgium. |
Collet, A., Desaive, T., Pierard, L., Boman, R., & Dauby, P. (2011). Influence of thermoelectric coupling on pacemaker activity generated by mechano-electric feedback in a one-dimensional ring-shaped model of cardiac fiber. In XXIIIrd congress of the International Society of Biomechanics, July 3-7, 2011 (pp. 208). Brussels, Belgium: International Society of Biomechanics. Peer reviewed |
Collet, A., Desaive, T., Pierard, L., Boman, R., & Dauby, P. (01 June 2011). Influence of thermoelectric coupling on pacemaker activity generated by mechano-electric feedback in a one-dimensional ring-shaped model of cardiac fiber [Poster presentation]. 2011 NHLBI /VCU - World Congress on Mathematical Modeling and Computational Simulation of Cardio vascular and Cardiopulmonary Dynamics, Williamsburg, VA, United States. |
Collet, A. (2011). Dynamique et chimie dans l'atmosphère de la face nocturne de Vénus. Sarrebruck, Germany: Éditions Universitaires Européennes. |
Collet, A., Cox, C., & Gérard, J.-C. (December 2010). Two-dimensional time-dependent model of the transport of minor species in the Venus night side upper atmosphere. Planetary and Space Science, 58. doi:10.1016/j.pss.2010.08.016 Peer Reviewed verified by ORBi |
Collet, A., Desaive, T., Pierard, L., Boman, R., & Dauby, P. (2010). Influence of thermoelectric coupling on ectopic beats generated by mechano-electric feedback (MEF) in a one-dimensional cardiac fiber model. In 9th Belgian Day on Biomedical Engineering, Friday November 26th 2010 in the Academy Palace, Hertogstraat 1, 1000 Brussels. Peer reviewed |
Collet, A., Desaive, T., Pierard, L., Boman, R., & Dauby, P. (26 November 2010). Influence of thermoelectric coupling on ectopic beats generated by mechano-electric feedback (MEF) in a one-dimensional cardiac fiber model [Poster presentation]. 9th Belgian Day on Biomedical Engineering, Bruxelles, Belgium. |
Collet, A. (2009). Modèle bidimensionnel instationnaire du transport de constituants minoritaires dans l'atmosphère nocturne de Vénus [Master’s dissertation, ULiège - Université de Liège]. ORBi-University of Liège. https://orbi.uliege.be/handle/2268/23846 |